Two-stage / with cord, plug, and switch
|
 |
| |
ULVAC KIKO's GLD Series are superior-type
pumps featuring high performance, low vibration, low
noise, and many excellent functions as described below.
Gas-ballasting to prevent vapor (i.e. water) from condensing
in the pump oil.
A forced oil supply mechanism which helps maintain oil lubrication
and pumping speeds over the entire pumping range from atmosphere
to high vacuum.
An anti-suckback device which protects the vacuum chamber in
the event of power failure.
The low temperature enables the pump to produce improved levels
of vacuum. A forced oil filter can be easily connected to filtering
contaminates from the oil and the oil condition can be checked
using a large, easy-to-read level gauge. |
|
| |
Unit |
50Hz |
60Hz |
| Actual Pumping Speed |
L/min. |
50 |
60 |
| Ultimate pressure |
Pa |
6.7 x 10-2 (6.7×10-1)(G.V.
Closed)
(6.7 ) (G.V.open)
|
| Motor |
|
Single
phase,100V(50/60Hz)/110V(60Hz),200W,
4 poles, split phase starting |
| Full load current |
A |
5.6 |
4.8(100V) |
5.1(110V) |
| Oil capacity |
mL |
500 – 800 |
| Recommended oil |
|
SMR-100 |
| Weight |
kg |
13.9 |
| Inlet port diameter |
mm |
KF-25 |
| Ambient operation temp.range |
°C |
7 – 40 |
| Dimensions |
mm |
165.5(W)
x 399(L) x 222.7(H) |
|
|
| *Ultimate pressure is measured with Macleod gauge. In ( ) shows the measurements with Pirani gauge. |
| In order to fully realize
the benefits of this high performance pump, the following should
be considered: |
| 1. |
GLD Series pumps operate
over a wide range-they can attain very low ultimate vacuum
(10-2 Pa) and use KF flanges which are
designed to achieve high vacuum. Use of high vacuum flanges
is recommended for best performance. |
| 2. |
GLD Series pumps are
not recommended for applications involving toxic or corrosive
gases. (See GCD Series : p.10) |
| 3. |
An oil-sealed rotary
pump is not recommended for continuous operation near atmospheric
pressure. |
Optional suction port
|
|
Size
|
Note
|
| KF-25 suction port |
KF-25 X
(40X40) |
Attached to standard
type
|
| Suction pipe for hose |
Dia.8 |
Option. 40X40adapter is needed, use
the suction pipe /40X40 adapter
|
| Suction pipe for hose |
Dia.12 |
Option. 40X40adapter is needed, use
the suction pipe /40X40 adapter
|
| Suction pipe for hose |
Dia.15 |
Option. 40X40adapter is needed, use
the suction pipe /40X40 adapter
|
| Suction pipe for hose |
Dia.18 |
Option. 40X40adapter is needed, use
the suction pipe /40X40 adapter
|
| Suction pipe for hose |
Dia.22 |
Option. 40X40adapter is needed, use
the suction pipe /40X40 adapter
|
| Suction pipe for hose |
Dia.27 |
Option |
| A type suction pipe |
PT1/4-L20,male |
Option. 40X40adapter is needed, use
the suction pipe /40X40 adapter
|
| B type suction pipe |
PT1/4-L20,female |
Option. 40X40adapter is needed, use
the suction pipe /40X40 adapter
|
| C type suction pipe |
PT1/4-L10,male |
Option. 40X40adapter is needed, use
the suction pipe /40X40 adapter
|
|
Optional exhaust port
|
|
Size
|
Note
|
| Exhaust port cap |
-
|
Attached to
standard type
|
| Exhaust pipe for hose |
Dia.12 |
Option |
| Exhaust pipe for hose |
Dia.15 |
Option |
| Exhaust pipe for hose |
Dia.18 |
Option |
| KF-16 exhaust port |
KF-16 |
Option |
| KF-25 exhaust port |
KF-25 |
Option |
|
Trap for exhaust side
|
|
Model
|
Note
|
| Oil-mist trap |
OMT-050A |
Option |
| Oil-mist
trap |
OMT-100A |
G3/4-G1 adapter is needed, use OMT-100A
/ adapter
|
| In-line type oil-mist trap |
OMI-100 |
G3/4-G1 adapter is needed, use OMI-100
/ adapter
|
|
Trap for suction side
|
|
Model
|
Note
|
| For-line trap |
OFI-050C |
Prevent counter flow of oil diffusion
into vacuum chamber, Need KF-25 clamp for attaching
|
| For-line trap |
OFI-050V |
Prevent mixing powder or liquid into
the pump, Need KF-25 clump for attaching
|
|
| Voltage |
Applicable
Volt |
CE Marked |
CSA Marked |
cTUVus Marked |
| Single phase, 100V |
Standard |
|
|
|
| Single phase, 110V (60Hz) |
Standard |
|
|
|
|