Two-stage / with cord, plug, and switch / with
thermal protector
|
 |
| |
ULVAC KIKO's GHD Series of direct drive, oil-sealed rotary vacuum pumps offers premium features including: anti-suck back valve, gas ballast valve, forced oil lubrication and thermal protection. GHD Series pumps also offer compact size and low noise/low vibration operation for built-in and desktop applications. |
|
| |
Unit |
50Hz |
60Hz |
| Actual Pumping Speed |
L/min. |
120 |
144 |
| Ultimate pressure |
Pa |
6.7 x 10-2 (G.V.closed) (6.7 x 10-1 )
6.7 (G.V.open)
|
| Motor |
mm |
Single
phase,100V,300W,2 poles,capacitor run |
| Full load current |
A |
5.5 |
5.0 |
| Oil capacity |
mL |
600 |
| Recommended oil |
|
R-2 |
| Weight |
kg |
17 |
| Inlet port diameter |
mm |
KF-25 |
| Ambient operation temp.range |
°C |
7 – 40 |
| Dimensions |
W x L x H (mm) |
132
x 367 x 217 |
|
| *Ultimate pressure is measured with Macleod gauge. In ( ) shows the measurements with Pirani gauge. |
| GHD Series pumps offer upgraded performance over G Series pumps for many applications; however, the following points need be considered in its selection: |
| 1. |
GHD Series pumps operate over a wide range they can attain very low ultimate vacuum (10-2 Pa) and use KF flanges which are designed to achieve high vacuum. Use of high vacuum flanges is recommended for best performance. |
| 2. |
GHD Series pumps are not recommended for applications involving toxic or corrosive gases. (See GCD Series). |
| 3. |
An oil-sealed rotary pump is not recommended for continuous operation near atmospheric pressure. |
Optional suction port
|
Size |
Note |
| KF-25 suction port |
KF-25 X
(40X40) |
Attached to standard
type |
| Suction pipe for hose |
Dia.8 |
Option. 40X40adapter is needed, use
the suction pipe /40X40 adapter |
| Suction pipe for hose |
Dia.12 |
Option. 40X40adapter is needed, use
the suction pipe /40X40 adapter |
| Suction pipe for hose |
Dia.15 |
Option. 40X40adapter is needed, use
the suction pipe /40X40 adapter |
| Suction pipe for hose |
Dia.18 |
Option. 40X40adapter is needed, use
the suction pipe /40X40 adapter |
| Suction pipe for hose |
Dia.22 |
Option. 40X40adapter is needed, use
the suction pipe /40X40 adapter |
| Suction pipe for hose |
Dia.27 |
Option |
| A type suction pipe |
PT1/4-L20,male |
Option. 40X40adapter is needed, use
the suction pipe /40X40 adapter |
| B type suction pipe |
PT1/4-L20,female |
Option. 40X40adapter is needed, use
the suction pipe /40X40 adapter |
| C type suction pipe |
PT1/4-L10,male |
Option. 40X40adapter is needed, use
the suction pipe /40X40 adapter |
|
Optional exhaust port
|
Size |
Note |
| Exhaust port cap |
- |
Attached to standard
type |
| Exhaust pipe for hose |
Dia.27 |
Option |
| KF-25 exhaust port |
KF-25 |
Option |
|
Trap for exhaust side
|
Model |
Note |
| Oil-mist trap |
OMT-100A |
Option |
| In-line type oil-mist trap |
OMI-100 |
Option |
|
Trap for suction side
|
Model |
Note |
| For-line trap |
OFI-200C |
Prevent counter flow of oil diffusion
into vacuum chamber, Need KF-25 clamp for attaching |
| For-line trap |
OFI-200V |
Prevent mixing powder or liquid into
the pump, Need KF-25 clump for attaching |
|
| Voltage |
Applicable
Volt |
CE Marked |
CSA Marked |
cTUVus Marked |
| Single phase, 100V |
Standard |
|
|
|
|