Two-stage / with cord, plug, and switch / with
thermal protector
|
 |
| |
ULVAC KIKO's GCD Series of direct
drive, oil-sealed rotary vacuum pumps offer corrosion-resistant
construction for applications involving toxic or corrosive
gases. This pump is ideal for applications in the chemical,
semiconductor, and pharmaceutical industries. Three different
models provide a range of pumping capacities from 50
L/min. to 200L/min..
|
|
| |
Unit |
50Hz |
60Hz |
| Actual Pumping Speed |
L/min. |
50 |
60 |
| Ultimate pressure |
Pa |
6.7 x 10-2 (6.7×10-1) (G.V.closed)
(6.7) (G.V. Closed) |
| Motor |
|
Single
phase, 220V(50/60Hz), 200W,
4 poles, split phase starting |
| Full load current |
A |
2.5 |
2.2 |
| Oil capacity |
mL |
500 – 800 |
| Recommended oil |
|
SO-M |
| Weight |
kg |
14.1 |
| Inlet, outlet pipe diameter |
mm |
KF-25 |
| Ambient operation temp.range |
°C |
7 – 40 |
| Dimensions |
mm |
165.5(W)
x 423(L) x 222.7(H) |
|
| *Ultimate pressure is measured with Macleod gauge. In ( ) shows the measurements with Pirani gauge. |
| 1. |
Use only Synthetic oil
(SOM) for pumping oil in GCD Series pumps. |
| 2. |
Consult your local sales
representative before pumping any toxic or corrosive gases. |
| 3. |
Oil rotary pump is not
recommended for continuous operation by near to the atmospheric
pressure. |
Optional suction port
|
|
Size
|
Note
|
| KF-25 suction port |
KF-25 X
(40X40) |
Attached to standard
type
|
| Suction pipe for hose |
Dia.8 |
Option. 40X40adapter is needed, use
the suction pipe /40X40 adapter
|
| Suction pipe for hose |
Dia.12 |
Option. 40X40adapter is needed, use
the suction pipe /40X40 adapter
|
| Suction pipe for hose |
Dia.15 |
Option. 40X40adapter is needed, use
the suction pipe /40X40 adapter
|
| Suction pipe for hose |
Dia.18 |
Option. 40X40adapter is needed, use
the suction pipe /40X40 adapter
|
| Suction pipe for hose |
Dia.22 |
Option. 40X40adapter is needed, use
the suction pipe /40X40 adapter
|
| Suction pipe for hose |
Dia.27 |
Option |
| A type suction pipe |
PT1/4-L20,male |
Option. 40X40adapter is needed, use
the suction pipe /40X40 adapter
|
| B type suction pipe |
PT1/4-L20,female |
Option. 40X40adapter is needed, use
the suction pipe /40X40 adapter
|
| C type suction pipe |
PT1/4-L10,male |
Option. 40X40adapter is needed, use
the suction pipe /40X40 adapter
|
|
Optional exhaust port
|
|
Size
|
Note
|
| KF-25 exhaust port |
KF-25 |
Option |
| Exhaust pipe for hose |
Dia.12 |
Option |
| Exhaust pipe for hose |
Dia.15 |
Option |
| Exhaust pipe for hose |
Dia.18 |
Option |
| KF-16 exhaust port |
KF-16 |
Option |
|
Trap for exhaust side
|
|
Model
|
Note
|
| Oil-mist separators |
OMC-050 |
Need KF-25 clamp for attaching
|
| For-line trap |
OFI-050V |
Prevent mixing powder or liquid into
the pump, Need KF-25 clump for attaching
|
| For-line trap |
OFI-050C |
Prevent counter flow of oil diffusion
into vacuum chamber, Need KF-25 clamp for attaching
|
|
Trap for suction side
|
|
Model
|
Note
|
| For-line trap |
OFI-050C |
Prevent counter flow of oil diffusion
into vacuum chamber, Need KF-25 clamp for attaching
|
| For-line trap |
OFI-050V |
Prevent mixing powder or liquid into
the pump, Need KF-25 clump for attaching
|
|
| Voltage |
Applicable
Volt |
CE Marked |
CSA Marked |
cTUVus Marked |
| Single phase, 100V |
Standard |
|
|
|
| Single phase, 110V (60Hz) |
Standard |
|
|
|
| Three phase, 200-460V |
 |
|
|
|
|