Diaphragm Type Dry Vacuum Pumps (Chemical Type) DTC-41
Two-stage / with thermal protector

 
Features

All contacted parts of the gas are made of PTFE and FPM.
Suitable for pumping out corrosive gas or organic solvent.
High vacuum down to 1000Pa.
Compact.

Specifications
  Unit 50Hz 60Hz
Actual Pumping Speed L/min. 40 46
Ultimate pressure Pa 1.0 x 103
Motor   Single phase, 220V, 100W, 4P, Capacitor run
Full load current A 1.10
Weight kg 10.3
Inlet, outlet pipe diameter mm O.D. 9 x I.D. 6 (G1/4)
Ambient operation temp.range °C 0 – 40
Dimensions mm 155(W) x 336.5(L) x 217(H)

Caution
It is necessary to present the pumping of water (or liquid), dust.

Outline drawing



Pumping Speed Curves
Optional voltage
Voltage Applicable Volt CE Marked cTUVus Marked
Single phase, 100V Standard  
Single phase, 115V    
Single phase, 200V    
Single phase, 220V    